6.2.9. ARM
Syntax:
ARM
ARM?
Form:
Set & Query
Description:
Query state (enable or disable) of “TRIG IN” input or enable/disable
“TRIG IN” input for single shot mode (Same function as the “RUN/STOP”
button on the front panel or “Run” light/button on web page)
Parameter:
Set: none (change the actual state to the other)
Query: 0 => disable (STOP)
1 => enable (RUN)
RST value:
Disable (STOP)
Example:
Enable “TRIG IN” input: ARM
Query “TRIG IN” state: ARM? (Answer: :ARM 1)