V1.1 2011
:INITiate Subsystem
The
:INITiate subsystem controls
the
s
tate
of the
Model
845-M
trigger
system.
The subsystem
commands
and paramet
er
s
are
described
below. The
:INITiate commands,
along with
the
:ABORt
and
:TRIGger commands, comprise
the Trigger Group of commands.
Command Parameters
Unit
(defa
u
lt)
Remar
k
:INITiate[:IMMediate]
ON
V0.3.10
:INITiate:CONTinuous ON|OFF|1|0
OFF
V0.3.10
:INITiate[:IMMediate]
Sets Model
845-M
trigger to the armed state.
:INITiate:CONTinuous
ON|OFF|1|0
Continuously rearms
the
Model
845-M
trigger
system
after
completion
of a
trigge
red
sweep.