Bnc 835 Programmer Manual Manuale Utente Pagina 28

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 65
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 27
Berkeley Nucleonics Corporation 2955 Kerner Blvd., San Rafael, CA 94901
Phone: 415-453-9955, Fax: 415-453-9956, Email: [email protected], Web: www.berkeleynucleonics.com
5.6 [SOURce]:PHASe Subsystem
Command
Parameters
Unit
(default)
Remark
[SOURce]:PHASe:REFerence
[SOURce]:PHASe[:ADJust]
<value>
0 radians
:PHASe:REFerence
[SOURce]:PHASe:REFerence
This command sets the current output phase as a zero reference. Subsequent phase adjustments are
set relative to the new reference.
:PHASe[:ADJust]
[SOURce]:PHASe[:ADJust] <value><unit>
[SOURce]:PHASe[:ADJust]?
This command adjusts the phase of the signal. The query will only return values in radians.
*RST The preset value is 0.